KTS F1 CHARACTERISTIC VALUES
maximum tensile loads *

Plug type

Construction material

KT 10

[KN]

KT 14

[KN]

Concrete, EN 206-1 C12/15 3,5 5,0
Concrete, EN 206-1 ≥ C16/20 5,0 7,5
Clay brick DIN EN 771-1, Mz 20-1, 8-NF (ß=20) 4,0 4,5
Solid sand-lime brick DIN EN 771-2, KS 12-1, 8-NF (ß=20) 1,5 1,5
Solid sand-lime brick DIN EN 771-2, KS 12-2, 0-2DF (ß=20) 4,0 4,5
Hollow clay brick DIN EN 771-1, HLz 12-1, 0-2DF 1,5 -
Hollow sand-lime brick DIN EN 771-2, KS L 12-1, 4-8DF 1,2 -
other on request on request
maximum bending moment *

Plug type

Screw material

KT 10

[Nm]

KT 14

[Nm]

Galvanized steel 12,8 36,2
Stainless steel 11,5 32,6
* Please note the relevant details and information in ETA 08/0188